Measuring Pro Station – Operating instructions
IO-Link
Port
Components
1
Valve manifold measuring
module
2
Displacement sensor
3
Indicator light
Interconnection within the station
24
Function
Rotary cylinder to the measurement table
Rotary cylinder to the second module
Lift gripper
Open gripper
Advance measuring cylinder
Measuring cylinder position
Measurement result indication
In the case of IO link, all signals are transmitted via an IO link multi protocol module,
which addresses the signals with different protocols depending on the controller.
Siemens PLC: ProfiNet,
Allen Bradley PLC: Ethernet IP,
Codesys PLC: IO link
Reference designation
-MB1
-MB2
-MB3
-MB4
-MB5
-BG6
-PF1