cap.05 EU65is 6500is (Eu).qxd 07.12.17 4:50 PM ページ5-1
5. BATTERY
1. BATTERY ............................................. 5-1
1. BATTERY
a. REMOVAL/INSTALLATION
Hydrogen gas from batteries is highly flammable and
explosive.
You can be burned or seriously injured when charging
battery.
• Keep heat, sparks, and flame away.
• The battery is a Valve Regulated Lead Acid (VRLA)
maintenance-free battery, so do not add any battery fluid.
• The battery is specially designed, so use correct battery (YTZ-
14S) only.
• When removing the battery, disconnect the negative (–) cable
first, then disconnect the positive (+) cable.
• When installing the battery, connect the positive (+) cable
first, then the negative (–) cable.
[8]
T42:
POSITIVE (+)
TERMINAL
5-1
WARNING
[1] TERMINAL
NUT (2)
[7] TERMINAL
BOLT (2)
[6] BATTERY BAND
[2] BATTERY (YTZ-14S)
REMOVAL/
INSTALLATION:
• Remove or install
the
battery
by
tipping it as shown.
• Install the battery
with the terminals
facing to the front.
INSPECTION: P. 5-2
CHARGING: P. 5-2
[3]
T41:
NEGATIVE (–)
TERMINAL
[4] BATTERY
MAINTENANCE
COVER BOLT
2.3 N . m (0.2 kgf . m,
1.7 lbf . ft)
[5]
BATTERY
MAINTENANCE
COVER