cap.12 EU65is 6500is 07.12.17 5:04 PM ページ12-4
b. INSPECTION
• STARTER SOLENOID
Connect a 12V battery to the starter solenoid terminal and
starter solenoid body as shown.
There should be continuity between the battery and starter
motor terminals.
There should be no continuity when the battery is
disconnected.
Be sure the battery is in good condition before performing this
test.
• BRUSH LENGTH
Measure the brush length.
If brush length is less than service limit, replace the brush.
Standard
10 mm (0.39 in)
• ARMATURE
<Mica depth>
When the mica is clogged, or its depth is smaller than the
service limit, recut the grooves using a hacksaw blade or a
small file.
Service limit
<Continuity check-commutator segments>
Check for continuity between the segments. If an open circuit
(no continuity) exists between any two segments, replace the
armature.
12-4
Service limit
6.0 mm (0.24 in)
0.2 mm (0.01 in)
0.2 mm
(0.01 in)

Publicidad