Descargar Imprimir esta página

Honda Motor EU65is Manual De Instrucciones página 368

Publicidad

cap.11 EU65is 6500is 07.12.17 5:03 PM ページ11-7
4) Check for any foreign material attached to the inside of the
rotor before installation. Install the rotor by aligning the key
groove with the woodruff key on the crankshaft.
Note that the magnetic force of the rotor is very strong.
Take care not to pinch your fingers during installation.
5) Apply oil to the threads of the 16 mm special nut. Holding
the rotor with a commercially available strap wrench,
tighten the 16 mm special nut to the specified torque.
TORQUE: 113 N . m (11.5 kgf . m, 83 lbf . ft)
c. INSPECTION
• GENERATOR
Voltage inspection
1) Remove the inverter unit (P. 6-2).
2) Pull the recoil starter and measure the voltage between the
terminals of the
mounted.
Specified Voltage: AC 15V or more
Coil
Connector Terminal number
Master
Slave
3) If the output voltage is less thasn the standard voltage.
Measure the resistance between the terminals of the
and
connectors according to the table below.
Coil
Connector Terminal number Standard resistance
Master
Slave
11-7
and
connectors with generator
Specific voltage
1 - 2
2 - 3
AC 15V min.
1 - 3
1 - 2
2 - 3
AC 15V min.
1 - 3
1 - 2
2 - 3
0.44 - 0.62 Ω
1 - 3
1 - 2
2 - 3
0.44 - 0.62 Ω
1 - 3
[1]
ROTOR
[2]
STRAP WRENCH
(Commercially
available)
[1]
GENERATOR WIRE HARNESS
[2] RED TAPE MARK
[3]
Viewed from terminal side

Publicidad

Capítulos

loading

Este manual también es adecuado para: