Parameter menu

PARAMETER
PARAMETER
VALUE

Selecting automation system model

WARNING! If this parameter is not set correctly, the automation system may not function properly.
N.B.: in the event of a reset to restore the default parameters, this parameter must be set again manually.
BG30/1600 - IRREVERSIBLE motor for gate leaves up to 1600 Kg.
BG30/2200 - IRREVERSIBLE motor for gate leaves up to 2200 Kg.
BG30/1000/HS - High Speed IRREVERSIBLE motor for gate leaves up to 1000 kg (see chapter 14 "Special
Parameters for High Speed Motor").
BG30/1400/R - REVERSIBLE motor for gate leaves up to 1400 kg (see chapter 15 "Special Parameters
for REVERSIBLE Motor").
BG30/1800/HS - High Speed IRREVERSIBLE motor for gate leaves up to 1800 kg (see chapter 14 "Special
Parameters for High Speed Motor").
BG30/1500/HS - High Speed IRREVERSIBLE motor for gate leaves up to 1500 kg (see chapter 14 "Special
Parameters for High Speed Motor").

Automatic closure after pause time (from gate completely open)

Disabled.
From 1 to 15 of gate closure attempts after photocell is triggered.
Once the number of attempts set is reached, the gate remains open.
The gate tries to close inde nitely.

Automatic gate closing after mains power outage

Disabled. The gate does not close automatically when mains power is restored.
Enabled. If the gate is NOT completely open, when mains power is restored, the gate closes after a 5 second
warning signalled with the ashing light (independently of the value set with the parameter
in "position recovery" mode (see chapter 20).

Selecting step mode control function (PP)

Open-stop-close-stop-open-stop-close...
Condominium function: the gate opens and closes after the set automatic closing time.
The automatic closing timer restarts if a new step mode command is received.
Step mode commands are ignored while the gate is opening. This allows the gate to open completely and prevents
the gate from closing when not required.
If automatic closing is disabled (
.
Condominium function: the gate opens and closes after the set automatic closing time.
The automatic closing timer does NOT restart if a new step mode command is received.
Step mode commands are ignored while the gate is opening. This allows the gate to open completely and prevents
the gate from closing when not required.
If automatic closing is disabled (
.
Open-close-open-close.
Open-close-stop-open.

Pre- ashing

Disabled. The ashing light is activated during opening and closing manoeuvres.
Flashing warning signal for 1 to 10 seconds prior to every manoeuvre.
5 second ashing warning signal prior to closing manoeuvre.
68
), the condominium function automatically attempts a closing manoeuvre
), the condominium function automatically attempts a closing manoeuvre
). The gate closes