10.3
Tightening torques
For the purpose of safety, the tightening torques listed
in the following sections must be used during routine
maintenance or during repair.
10.3.1
Fastening parts
Tightening torques of the fastening parts:
Size
5.6
6.8
M 5
M 8
14 +3
M 10
M 12
M 14
90 +10
M 16
135 +10
10.3.2
Coupling halves
On the injection-pump camshaft
Size
Bevel gear
diameter [mm]
M 12
M 14 x 1,5
M 18 x 1,5
M 20 x 1,5
M 24 x 1,5
M 30 x 1,5
10.4
Machinery noise information
pursuant to the bench safety code
R
Noise measurement performed in accordance with DIN EN ISO 3744 and DIN EN ISO 11204 standards.
R
Sound power measurement performed in accordance with DIN ISO 3744 standard.
Test bench without injection pump Test bench with VE injection pump
Speed
n=0
Acoustic
72
power level A
LWA (Values
in dB)
Workplace-
58
related emis-
sion value LpA
Robert Bosch GmbH
8.8
10.9
5 +2
23 +3
32 +5
45 +8
65 +8
80 +8
125 +10
135 +10
210 +10
Tightening torque
[Nm]
17
60 +10
20
80 +10
25
130 +10
30
200 +20
35
250 +50
40
300 +50
n=750
n = 4000
96
81
Technical data | EPS 625 | 79
Measurement condition
n = 1360
97
102
85
87
Test bench with PE injection pump
n=500
n = 1150
99
111
83
96
|
1 689 988 258
2017-05-30
en