Storage And Transport - 3M DBI SALA ROLLGLISS R550 Instrucciones De Uso

Ocultar thumbs Ver también para DBI SALA ROLLGLISS R550:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 55
6.0
MAINTENANCE, SERVICING, STORAGE
6.1
cLEANING: Periodically clean the exterior of the R550 with water and mild detergent. Position the device so excess water
will drain out. Clean labels as required. Clean lifeline with water and mild detergent. Rinse and thoroughly air dry. Do not
force dry with heat. A buildup of dirt, paint, or other materials may prevent the lifeline from pulling through the device.
Ensure no knots are present.
Humidity Resistant case: If inspection of the Humidity Indicator per the "Inspection and Maintenance Log"
(Table 2) indicates that the Humidity Resistant Case has experienced high humidity, perform the following
maintenance:
1.
Replace the Pie Sector Indicator Disc: See Figure 13 for reference. Replacing the Pie Sector Indicator Disc
requires a new disc to be inserted within the Humidity Indicator. To replace the Indicator Disc:
• Grasp the Humidity Indicator by the Hex Flange (E) on the outside of the Humidity Resisitant Case.
• Insert a 1/2" hex wrench or Allen wrench (A) into the externally-threaded Collar (B) and turn the Collar
counter-clockwise to loosen.
• Remove the Collar (B) from the Humidity Indicator assembly.
• With the Humidity Indicator now open, remove the Teflon Washer (C) from within the assembly.
• Remove the old Pie Sector Indicator Disc (D) from the Humidity Indicator.
• Install a new Indicator Disc (9505223) within the Humidity Indicator.
• Place the Teflon Washer (C) back inside the Humidity Indicator, on top of the new Indicator Disc.
• Install the externally-threaded Collar (B) over the washer to secure the indicator disc assembly in place.
• Hold the Humidity Indicator by the Hex Flange (E) and torque the externally-threaded Collar (B) to 5-6 N-m
(3.69 - 4.43 ft-lb).
2.
Replace Moisture Absorber Packets: Just prior to resealing the humidity resistant case, replace all Moisture
Absorber Packets in the case with new Absorber Packets (9505148). Each new Moisture Absorber Packet is
wrapped in a foil bag. Remove the foil bag before placing the the new packet in the case.
6.2
SERvIcE: Only 3M or parties authorized in writing by 3M may make repairs to this equipment. If the R550 Device has
been subject to fall force or if inspection reveals an unsafe or defective condition, remove the system from service and
destroy.
6.3
STORAGE AND TRANSPORT: When not in use, store and transport the R550 Device in a cool, dry, clean environment
out of direct sunlight. Avoid areas where chemical vapors may exist. Thoroughly inspect the device after extended
storage. If the R550 Device cannot be stored in a properly suitable environment, a Humidity Resistant Case should be
used.
;
R550 Devices installed at a workstation and left in place between inspections should be adquately protected from
environmental conditions.
7.0
RFID TAG
7.1
LOcATION: 3M product covered in these user instructions is equipped with a Radio Frequency Identification (RFID) Tag.
RFID Tags may be used in coordination with an RFID Tag Scanner for recording product inspection results. See Figure [X]
for where your RFID Tag is located.
7.2
DISPOSAL: Prior to disposing of this product, remove the RFID Tag and dispose/recycle in accordance with local
regulations. For additional information on how to remove the RFID Tag, please refer to the website link below.
Do not dispose of your product as unsorted municipal waste. The crossed-out wheelie bin symbol indicates that
all EEE (Electrical and Electronic Equipment) must be disposed of according to local law through available return
and collection systems. Please contact your dealer or your local 3M representative for further information.
For more information, please visit our website: http://www.3M.com/FallProtection/RFID
All manuals and user guides at all-guides.com
15

Publicidad

Tabla de contenido
loading

Tabla de contenido