Maintenance plan
Check all fastening screws and anchors with a torque wrench.
Fastening class 8.8
0,08*
0,12**
0,14***
M8
17,9
23,1
25,3
M10 36
46
51
M12 61
80
87
M16 147
194
214
M20 297
391
430
M24 512
675
743
Festigkeitsklasse 10.9
0,08*
0,12**
0,14***
M8
26,2
34
M10 53
68
75
M12 90
117
128
M16 216
285
314
M20 423
557
615
M24 730
960
1060
*
Lubricated slide friction number 0.8 MoS2
**
Lightly oiled slide friction number 0.12
***
Ensured slide friction number 0.14 screw with micro-encapsulated
plastic
All weld seams must have a visual inspection. Stop the system and
contact the manufacturer if there are cracks or breaks in weld seams
of the lift.
Check the paint:
• Check the powder coating and improve if required. Damage by
external influences is to be treated immediately after detection. If
these points are not treated, infiltration of deposits of all kinds can
cause wide-ranging and permanent damage. These points are to
be lightly sanded (120 grit), cleaned and degreased. Afterwards,
rework with a suitable touch up paint (note the RAL No.).
• Check galvanized surfaces, touch up as needed. White rust is fos-
tered by permanent humidity, poor ventilation. The affected areas
can be treated by using a sanding cloth (A 280 grit). If required,
the parts are to be treated with a suitable, resistant material (paint
etc.). Check the RAL colour selection.
• Rust is brought out by mechanical damage, wear, aggressive de-
posits (de-icing salt, leaking operating fluids) cleaning that is not
done or incomplete. The affected areas can be treated by using a
sanding cloth (A 280 grit). If required, post-treat the areas with a
resistant material (paint etc.).
37,2