Behaviour in cases of error
Defective operational readiness of the lift may be due to
a simple error. Check the system for the listed sources of
error.
If the error cannot be removed after an inspection to the
named causes, then inform customer service or your deal-
er.
Independent repairs to the lift,
especially on the safety devices, as
well as inspections and repairs to
electrical systems are prohibited.
Work on electrical systems may
only be done by electricians.
Problem: Lift can neither be raised nor low-
ered
possible causes:
No power supply present
The main switch is not
switched on, or is defective
Defective reverse switch
Defective fuse
Power line interrupted
Motor has overheated
Plug connections not
plugged in or are loose on
the motors
The platform is not in the
control window
Polyflex belt is loose or
defective
Motor defective
112
Repair:
Check power supply
Check main switch
Have the reversing switch
checked
Check fuses
Check power lines
Let motor cool (cooling
time dependent on ambient
temperature)
Check the plug connections
on the motors
Do a manual equalization
(see Section 6.4)
Stop the lift and secure
against unauthorised use.
Exchange the polyflex belt
and align it. (see Section
7.3)
Do an emergency discharge
(see Section 6.1)
The lift is located in the
lowest position Safety de-
vices (capture hooks) are
activated
The lift is no longer in the
control range and has
switched off
Problem: The lift cannot be raised
possible causes:
Only 2 phases active
Polyflex belt is loose / torn Check / exchange and
Lift nut broken, safety
equipment (capture hook)
active, lifting rails are
no longer in their control
range and the lift has
switched off
Up Off is active
Problem: The lift cannot be lowered
possible causes:
Down Off is active
The lifting arm has moved
onto an obstacle and is out
of the control window
6.1 Moving onto an obstacle
If the lifting rails or a lifting arm have been moved onto
an obstacle due to inattention of the operator, only the
motor is blocked for the lifting rail or lifting arm sit-
ting on the obstacle. The lift switches off as soon as
the other lifting rail has moved out of the control range
of 64 mm. As an additional safety measure, there is a
temperature monitor integrated into the motor winding
which interrupts power if the motor is overloaded. Any
further operation of the lift is only possible after some
minutes have passed (cooling of the motor: depending
of the external temperature). After a motor is blocked
the v-belt must be checked for any possible damage
and exchanged if required. Please contact your service
partner (dealer).
OPI_SMART LIFT 2.30 SL-2.35 SL-2.40 SL_V4.4_DE-EN-FR-ES-IT
Lift nut defective
Contact customer service
Repair:
Do an on-site check with a
qualified electrician
align (see Section 7.3)
Stop the lift and secure
against unauthorised use,
contact customer service
The lift can only be lowered
Repair:
The lift can only be raised
Do a manual equalization

Publicidad

loading

Este manual también es adecuado para:

Smart lift 2.35 slSmart lift 2.40 sl