Made
in
Germany
8.6.4 Selection the Liebig anchor with floor cover (screed, tiles)
Hole diameter 26 mm in the baseplate
Liebig anchor
Anchor type
Drill depth (mm)
Min. anchoring depth (mm) b
Concrete thickness (mm)
Drill diameter (mm)
Component thickness (mm) e + f 40 – 65
Concrete quality
Number of anchors (pc.)
Torque of the anchors
(*) Min. concrete thickness when using the above-mentioned anchor, otherwise follow the details in the foundation
plans.
Similar value anchors and other known brands of anchor manufacturers can be used when considering the conditions.
(1) Description of normal reinforcement:
A normal reinforcement is present if the axis separation in the area of the anchor with a rod diameter of ≥ 10 mm
is 150 mm, or for a rod diameter of ≤ 10 mm is 100 mm.
130
BM16-25/100/65
a
125
100
c
min. 200*
d
25
Min.C20/25 normal reinforcement
depending on the lift type
115 Nm
BM16-25/100/100
125
100
min. 200*
25
65 – 100
1
115 Nm
OPI_SMART LIFT 2.30 SL-2.35 SL-2.40 SL_V4.4_DE-EN-FR-ES-IT