Motor [kW]
4
5.5
7.5
11
*
C1, if equipped with an external Grundfos EMC filter.
Immunity: The motor fulfils the requirements for industrial areas.
Contact Grundfos for further information.
8.5.3 Enclosure class
Standard: IP55 (IEC 34-5).
Optional: IP66 (IEC 34-5).
8.5.4 Insulation class
F (IEC 85).
8.5.5 Standby power consumption
5-10 W.
8.5.6 Cable entry sizes
Number and size of cable entries
Motor [kW]
0.25 - 1.5
2.2
3.0 - 4.0
5.5
7.5 - 11
Related information
4.1.2 Cable entries
8.5.7 Torques for terminals
Terminal
L1, L2, L3, L, N
NC, C1, C2, NO
1-26, A, Y, B
8.5.8 Sound pressure level
Rated maximum
Motor
speed
[kW]
-1
[min
]
2000
0.25 - 0.75
4000
5900
2000
1.1
4000
5900
68
1450-2000 min
C3/C1
C3/C1
-1
1450-2200 min
4 x M20
1 x M25 + 4 x M20
1 x M25 + 4 x M20
1 x M32 + 5 x M20
1 x M32 + 5 x M20
Thread size
M4
M2.5
M2
-1
Speed [min
]
1500
2000
3000
4000
4000
5900
1500
2000
3000
4000
4000
5900
Emission category
-1
C1
*
-
-1
2900-4000 min
4 x M20
4 x M20
1 x M25 + 4 x M20
1 x M25 + 4 x M20
1 x M32 + 5 x M20
Maximum torque [Nm]
2.35
0.5
0.5
Sound pressure level
1 x 200-240 V
3 x 200-240 V
37
-
43
-
50
-
60
-
58
-
68
-
-
-
-
-
50
50
60
57
58
-
68
-
-1
2900-4000 min
-1
4000-5900 min
C1
C1
*
C3/C1
*
C3/C1
-1
4000-5900 min
4 x M20
4 x M20
1 x M25 + 4 x M20
1 x M25 + 4 x M20
1 x M32 + 5 x M20
ISO 3743
[dB(A)]
3 x 380-500 V
37
43
50
60
58
68
37
43
50
60
58
68