9. INSTALLATION INSTRUCTIONS AND DIMENSIONS
Ventilation
B
6:1
The open channel at the rear is clearly shown. For proper operation of the unit it is important
that the top of the housing unit is not blocked. A channel depth of 40-50 mm is normal for
most units. A ventilation hole in the base of the unit is necessary to allow air to enter over
the compressor and heat exchanger.
As a general rule, the more air that can flow in and out, the better and more efficient the
product performance.
The main consideration when installing any refrigeration
unit in a fitted kitchen is ventilation. The heat extracted
from the refrigeration compartment must be dissipated
into the atmosphere. Improper ventilation can lead to
premature compressor failure, excessive energy
consumption, total system failure and may invalidate the
warranty provided with the unit. the appliance. For
products intended to be installed
unit,
the
following requirements must be met:
A
B
C
in
a
wall
A
6:1
C
6:1
INOXPAN S.L. - 110
EN