An effective grounding connection is essential for correct operation of the machine.
Make sure the available pressure and the rendered capacity of the compressed air system
are compatible with those required for correct machine operation - see the "Technical Data"
section. For correct machine operation, the compressed air supply line must provide a
pressure range from no less than 8.5 bar to no more than 16 bar and guarantee an air flow
rate greater than the average consumption of the machine, which is equal to 187 Nl/min.
For correct equipment operation, the air produced must be suitably treated (not
above 5/4/4 according to ISO 8573-1)
Check that the Lubricator unit B fig. 2a contains air lubricating
oil; top up if necessary. Use SAE20 oil.
The customer must provide an air cut-off valve upstream of the
air treatment and regulator device supplied with the machine.
Before making the electrical and pneumatic hook-ups,
make sure that the machine is configured as described
below:
- pedals A and B (if present) in fully depressed
position.
- column C vertical (not tilted).
88
NOTICE
NOTICE
DANGER
FITLINE 32 - 32 2V - 32 GP - 32 GP 2V
User Manual
2a
C
B
A
B