18. Troubleshooting
Problem
LED Display (3) does not
switch on when Front
Flap (2) is closed
SOLID red LED (3c) on
the LED Display (3)
Flashing red LED (3c),
while green LED is
on (3a)
SOLID yellow LED (3b),
while green LED is
on (3a)
Possible Cause
Battery fully discharged
Front Flap (2) not correctly
positioned on the hook-and-
loop patch
Gas inflators empty
and/or
airbag must be replaced
System Error
Battery Low
It is performing the System
Check.
Possible Solutions
Recharge battery (Section 11) and
check the correct LED behavior during
the recharge.
Check the correct alignment between
Front Flap (2) and hook-and-loop patch.
After a deployment, the gas inflators
must be replaced. Until such replacing,
the System will not work even though
the battery is charged and the LED
Display (3) will show the red light until
the gas inflators are replaced.
If the number of left deployment is 0,
the red LED (3c) will signal a System
fault even after the gas inflators
replacement. In this case, the airbag
itself must be replaced and the System
reactivated by the authorized dealer
where the System was purchased.
The System has an error. Contact he
authorized dealer where the System
was purchased to check the System.
Remaining battery level is lower than
4 hours. Recharge the battery as soon
as possible.
Normal operation to enter in the
protecting airbag mode.
27 EN

Publicidad