Roger Technology B70/2DC Instrucciones Y Advertencias Para El Instalador página 31

Centrale di comando 2 motori
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74
21 30
Pause time for automatic reclosing
00
90
SECONDS
-
92
99
from 2 to 9 MINUTES
-
NOTE: parameter
When one of the photocells is obscured the timer is reset and the count restarts upon the return of
the safety protection at pause.
25 03
Phase shift when opening (for motor 2)
00
10
SECONDS
-
26 05
Phase shift when closing (for motor 1)
00
30
SECONDS
-
NOTE: parameter
27 03
Time taken to move back after the intervention of the safety edge or the anti-crushing protection
00
60
SECONDS
-
Establishes how many seconds the reversal operation on obstacle lasts; set to a value high enough
to reach the opening limit switch it also performs automatic reclosing according to parameter
29 01
Electric lock
00
DEACTIVATED
01
ENABLED
The activation starts 0.5 seconds before the start of the operation and lasts for 2 seconds.
30 05
Fine adjustment of the impact forces (combined with par. 31 and 32)
1 = -8%, 2 = -6%, 3 = -4%, 4 = -2%
01
09
5 = 0%
-
6 = +2%, 7 = +4%, 8 = +6%, 9 = +8%
NOTE: increasing / decreasing the parameter increases / decreases the nominal torque of the motors.
31 15
Impact force level motor 1
32 15
Impact force level motor 2
01
10
low torque motor : 1 minimum impact force ... 10 maximum impact force
-
11
19
medium torque motor : 11 minimum impact force ... 19 maximum impact force
-
20
Maximun torque motor : without any adjustment of the anti-crushing protection
NOTE: parameter
In order to fall within the limits of impact forces, usually use the values from
to be performed at each installation. The values from
11-19
are not adequate. The value
The torque values of low and medium engine can be modified by acting on the parameter
2-
in simplified mode.
4-
in simplified mode .
9-
A-
and
in simplified mode
20
01
10
to
should be used only in the presence of sensitive edges.
11
19
to
are to be used only in case the values
49
.
; the check is
30
.
31