34 08
Acceleration when starting motor 1
35 08
Acceleration when starting motor 2
01
10
1 = quick start ... 10 = very slow start
-
Can be set separately for both motors, thus adapting the control to the mechanical situation;
however you should always make sure the choice is appropriate, and does not cause wings which
may have had a phase shift to overlap.
A low value (
speed more slowly, thus allowing a more gentle and gradual start of the wing.
NOTE: these parameters can be changed even after you have programmed the stroke.
38 00
Pressure surge
00
ENABLE
01
DISABLE
Enabled in order to facilitate the release of the electric lock, which could be hindered by the leafs
that press on the coupling point (for example, due to the wind): the opening operation is preceded
by a short closing for no more than 4 seconds.
Enabling the pressure surge also automatically enables the electric lock.
The pressure surge is only performed when starting from the fully closed position, every opening operation is
performed until the position of the wings is known by carrying out a closing movement for 1.5" before opening.
40 05
Rated speed
01
05
1 = minimum speed ... 5 = maximum speed
-
01
The values
maximum speed.
49 00
Automatic reclosing attempts after safety edge or the anti-crushing protection intervention
does not automatically reclose after the safety edge or the anti-crushing protection
00
intervention
01
03
number of attempts at reclosing
-
If the value exceeds that of parameter
a2
parameter
50 00
Mode if photocell FT1 is interrupted when opening
00
IGNORE, no action or FT1 not installed
01
STOP, the gate remains stationary until the next command
02
REVERSE IMMEDIATELY, thus closing
03
TEMPORARILY STOP, the beam released, it continues to open
04
INVERT WHEN RELEASED, the beam released, it reverses thus closing
51 02
Mode if photocell FT1 is interrupted when closing
00
IGNORE, no action or FT1 not installed
01
STOP, the gate remains stationary until the next command
02
REVERSE IMMEDIATELY, thus closing
03
TEMPORARILY STOP, the beam released, it continues to open
04
INVERT WHEN RELEASED, the beam released, it reverses thus closing
32
01
) involves rapid acceleration, while a high value (
02
03
04
-
-
-
-
. Only recloses after the impact if it is moved back until fully open
05
respectively correspond 60%, 70%, 80%, 90% e 100% of the
a2
, it will be automatically considered to be equal to that of
10
) means reaching the operating