4. Select 32" (selection is highlighted with a green
border.
5. Position the demounting tool as shown in fig.
42c and use a feeler gauge to measure the
distance between the tool and the template,
which must be 3-3.5 mm.
6. Press
. The number 32 turns GREEN if
the position is correct. If not, the number turns
RED and the message "Calibration failed" is
displayed.
7. Lift the demounting tool.
8. Select 17" (selection is highlighted with a green
border).
9. Position the demounting tool as shown in fig.
37d and use a feeler gauge to measure the
distance between the tool and the template,
which must be 3-3.5 mm.
10. Press
. If the position is correct, the
number 17 turns GREEN and the message shown in Fig. 42e is displayed.
9. Lift the demounting tool.
10. Switch the machine off, then on again.
NEVER press x-axis calibration during the work phases but only during the calibra-
tion phase with the template mounted!
5.8.m. P3K DIAGNOSTICS
1. Select P3K DIAGNOSTICS then press the confirm
button
(Fig. 43).
2. At the end, Fig. 43a will be displayed.
150
42b
CAUTION!
42c
42d
42e
43
User manual S 1000