part nr 425083. Earth ground terminal.
1.2.c. ELECTRICAL AND PNEUMATIC CON-
NECTIONS
The electrical power line connecting the machine
must be suitably sized in relation to:
• the electric power absorbed by the machine,
indicated on its data plate (Fig. 1);
• the distance between the machine and the
electric hook-up point, so that voltage drops
under full load do not exceed 4% (10% when
starting up) of the rated voltage specified on
the data plate.
- The user must:
• fit a power plug on the power supply
lead in compliance with the relevant safety
standards;
• connect the machine to its own electrical
connection - A, Fig. 2 - and fit a differential
safety circuit-breaker with 30 mA residual
current;
• install protection fuses on the power line
that are suitably sized in accordance with
the indications provided on the machine
data plate (Fig. 1);
•connectthemachinetoanindustrialsocket;
the machine must not be connected to do-
mestic sockets.
An effective grounding connection is essential for correct operation of the machine.
Make sure the available pressure and the rendered capacity of the compressed air system are
compatible with those required for correct machine operation - see the "Technical Data" sec-
tion. For correct machine operation, the compressed air supply line must provide a pressure
range from no less than 8.5 bar to no more than 16 bar and guarantee an air flow rate greater
than the average consumption of the machine, which is equal to 160 Nl/min.