Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 107
Chapter 4
DANGER
DANGER
DANGER
8008684/YJC8/2015-03-30
2 5 6
8 008 684/RI57/2007-11-28

Mounting

SEL 1 and SEL 2 can be used to set the devices to the default state;
SEL 1 and SEL 2 are alternately connected to GND and then left open
again immediately after the device is switched on. The reset procedure
begins when, immediately after the device is switched on, the select
inputs are connected to GND for 2 seconds and the display changes
to s. The device then waits for the signal change within the following
2 seconds. If the sequence does not match the sequence expected
by the device, the device assumes the OFF state. If the reset proce-
dure has been performed successfully, "5" appears on the display.
Switching the device off and then on again returns it to its normal
operating state.
Reset procedure
The integrity of the system must be checked whenever a reset
procedure is performed.
The SEL 1 and SEL 2 cable must be wired up and insulated again.
4 4 4 4 4
Mounting
Follow the planning procedure as specified in the Technical
Description!
Before installing the devices on the basis of these operating instruc-
tions, a plan must be drawn up in accordance with the TECHNICAL
DESCRIPTION – SAFETY LIGHT CURTAIN C 2000/MULTIBEAM
PHOTOELECTRIC SAFETY SWITCH M 2000/SAFETY EVALUATION UNIT
LE 20. Compliance with the safety clearances established in the plan
is essential to the protective function of the devices.
Secure the devices against moving!
When installing, ensure that the safety devices cannot be subse-
quently knocked out of their fixed positions.
Multibeam Photoelectric Safety Switch M 2000
© SICK AG • Safety Systems • Germany • All rights reserved
Operating Instructions
Safety Light Curtain C 2000

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

M2000

Tabla de contenido