AMPROBE
ON = the instrument is able to face situations of CO-GENERATION
CO-GENERATION
OFF = the instrument will record ONLY the powers and energies
P1
Active Power
Q1i
Inductive Reactive Power
Q1c
Capacitive Reactive Power
S1
Apparent Power
Pf1
Power factor
dpft1
cosϕ
Ea1
Active energy
Eri1
Inductive reactive energy
Erc1
Capacitive reactive energy
The value of the network frequency is automatically selected if the voltage is selected.
The symbols "i" and "c" stand for reactive powers (Q), power factors (Pf) and cosϕ (dpf) inductive and capacitive respectively.
Selecting a power factor (Pf) or a cosϕ (dPf) for the recording automatically their inductive value and their capacitive value will be
recorded separately.
of electrical equipment (that is, the equipment under test is
able to generate energy besides absorbing it). Accordingly, the
instrument will record the powers and energies both absorbed
and generated (see paragraph 16.7.1). If this flag is enabled
the maximum number of parameters which can be
selected decrease to 38.
absorbed.
MULTITEST2000
☺
☺
P1
☺
Q1i Q1c
☺
S1
☺
Pf1 dPf1
☺
Ea1
☺
Eri1 Erc1