Plates And Symbols; Safety / Warning Symbols, Note Symbols; Name Plate - ABB CoriolisMaster FCB300 Serie Instrucciónes De Puesta En Marcha

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 165
1.5

Plates and symbols

1.5.1

Safety / warning symbols, note symbols

DANGER – Serious damage to health / risk to
life
This symbol in conjunction with the signal word
"DANGER" indicates an imminent danger. Failure
to observe this safety information will result in
death or severe injury.
DANGER – Serious damage to health / risk to
life
This symbol in conjunction with the signal word
"DANGER" indicates an imminent electrical
hazard. Failure to observe this safety information
will result in death or severe injury.
WARNING – Bodily injury
This symbol in conjunction with the signal word
"WARNING" indicates a potentially dangerous
situation. Failure to observe this safety
information may result in death or severe injury.
WARNING – Bodily injury
This symbol in conjunction with the signal word
"WARNING" indicates a potential electrical
hazard. Failure to observe this safety information
may result in death or severe injury.
CAUTION – Minor injuries
This symbol in conjunction with the signal word
"CAUTION" indicates a potentially dangerous
situation. Failure to observe this safety
information may result in minor or moderate
injury. The symbol may also be used for property
damage warnings.
NOTICE – Property damage
This symbol indicates a potentially damaging
situation.
Failure to observe this safety information may
result in damage to or destruction of the product
and / or other system components.
IMPORTANT (NOTE)
This symbol indicates operator tips, particularly
useful information, or important information about
the product or its further uses. The signal word
"IMPORTANT (NOTE)" does not indicate a
dangerous or harmful situation.
1.5.2

Name plate

IMPORTANT (NOTE)
The name plates shown here are only examples.
The name plates attached to the device may be
different to what you see here.
CoriolisMaster
ATEX
FM 12 ATEX0045
II 1/2G Ex d e [ia] [ib] IIC T6...T2>= DN50
II 2G
Ex d e [ia] [ib] IIC T6...T2<= DN40
II 2D
Ex tD A21 IP6X T115°C...T
II 2D
Ex tD [iaD] A21 IP6X T115°C...T
IECEx
IECEx FME 12.0004
Ga/Gb Ex d e [ia] [ib] IIC T6...T2>= DN50
Ex d e [ia] [ib] IIC T6...T2<= DN40
Ex tD A21 IP6X T115°C...T
Ex tD [iaD] A21 IP6X T115°C...T
Electrical data, ignition class of output circuits and
temperature classes, see EC-Type Examination Certificate.
CoriolisMaster
CL I, ZN 1, AEx d e [ia] IIC T6 CL I, ZN 2, AEx d e [ia] IIC T6
cFMus
CL I, ZN 1, AEx d e [ia] [ib] IIC T6 CL I, ZN 2, AEx d e [ia][ib] IIC T6
ZONE 21 AEx tD T115 °C... Tfluid Control Install Dwg No. MDM-10-A0281
XP: CL I, DIV 1, GP ABCD
DIP: CL II, III, DIV 1, GP EFG
IS: CL I, II, III, DIV 1, GP ABCDEFG
Control Install Dwg No. MDM-10-A0281
NI: CL I, II, III, DIV 2, GP ABCDEFG
Control Install Dwg No. MDM-10-A0291
Ex d e [ia] IIC T6
Ex d e [ia] [ib] IIC T6
DIP A21 TA T115 °C... Tfluid CL II, DIV 1, GP EFG
Control Install Dwg No. MDM-10-A0281
XP: CL I, DIV 1, GP BCD
DIP: CL II, DIV 1, GP EFG, CL III, DIV 1, 2, GP EFG
IS: CL I, II, III, DIV 1, GP ABCDEFG
Control Install Dwg No. MDM-10-A0281
NI: CL I, II, DIV 2, GP ABCDEFG
Control Install Dwg No. MDM-10-A0291
1
CoriolisMaster
2
Model no.: FCB350Y0Y0015E1D2A1C2D1A1A
3
Order no.: 000351160 / X001 / 000191
4
U/f nom:
100...230 V 50/60 Hz
5
Size:
DN 20 / IP 67
6
Fitting:
DN 25 / PN 40
7
Material:
1.4571
K:
40.375 Cal.: V: +/-0.4 % D: +/- 5 g/l
8
Qmax DN: 100 kg/min
9
Tmed: -50 °C...+180 °C Tamb: -20 °C....+60 °C
10
Software: FCB3 00.01.00
11
ABB Automation Products GmbH
37070 Göttingen – Germany
12
Fig. 1:
Flowmeter sensor, integral mount design (example)
1 Full designation | 2 Order code | 3 Order number |
4 Power supply | 5 Nominal diameter / Degree of protection |
6 Process connection / Pressure rating | 7 Meter tube material |
8 Calibration factor | 9 Maximum flow rate |
10 Medium temperature range | 11 Software version |
12 Manufacturer | 13 Year of construction (month / year) |
14 Ambient temperature range | 15 Communication |
16 Calibration accuracy | 17 PED mark |
18 Maximum power consumption | 19 Serial number of sensor |
20 CE mark | 21 Ex approval cFMus |
22 Ex approval ATEX / IECEx
CoriolisMaster FCB330, FCB350 | CI/FCB300-X1 Rev. C EN - 5
0044
Fluid
Fluid
Fluid
Fluid
Pmax: 25VA
PED.: xxx
Var.: HART
Year 02/2012
G10308-02
22
21
20
19
18
17
16
15
14
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Coriolismaster fcb330Coriolismaster fcb350

Tabla de contenido