8

Ex relevant specifications acc. to cFMus

8.1
Overview of the different output options
Versions
Version I
Output option A / B
in the order number
Version II
Output option D
in the order number
8.2

Electrical data for Div. 2 / Zone 2

8.2.1

Version I: Active / passive current outputs and Version II: passive / passive current outputs

Model FCB3xx-F2, FCT3xx-F2
Current output 1
Terminals 31 / 32
Current output 2
Terminals 33 / 34
Pulse output
Terminals 51 / 52
Switching output
Terminals 41 / 42
Switching input
Terminals 81 / 82
All inputs and outputs are electrically isolated from one other and from the power supply.
Class I Div. 2
— Current output 1: Active
— Current output 2: Passive
— Pulse output: Active / passive, switchable
— Switching input and output: Passive
Class I Div. 1
— Current output 1: Active
— Current output 2: Passive
— Pulse output: Passive
— Switching input and output: Passive
— Current output 1: Passive
— Current output 2: Passive
— Pulse output: Passive
— Switching input and output: Passive
Type of protection NI
(V)
Vmax
o
30
30
30
30
30
CoriolisMaster FCB330, FCB350 | CI/FCB300-X1 Rev. C EN - 39
(mA)
Imax
o
30
30
65
65
10