Transmitter Model Fct300 In Remote Mount Design; Hazardous Area Approval Atex / Iecex - ABB CoriolisMaster FCB300 Serie Instrucciónes De Puesta En Marcha

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 165
7.3

Transmitter model FCT300 in remote mount design

Ambient and process conditions:
T
-20 ... 60 °C (-4 ... 140 °F)
amb
Protection class
IP 65, IP 67, and NEMA 4X / Type 4X
7.3.1

Hazardous area approval ATEX / IECEx

Specific marking according to ATEX and IECEx applies depending on the design of the flowmeter sensor (integral or remote
mount design).
IMPORTANT (NOTE)
ABB reserves the right to make changes to the Ex-marking. The exact marking can be found at the name plate of the meter.
Model FCT3xx-Y0... (Transmitter outside the hazardous area, Sensor in Zone 0, 1 or 2)
Approval
Marking
ATEX
II (1) G [Ex ia] IIC
IECEx
[Ex ia Ga] IIC
Model FCT3xx-A2... (Transmitter in Zone 2, Sensor in Zone 0, 1 or 2)
Approval
Marking
ATEX
II 3(2) G Ex nA nR [ia] IIC T6
II 2 D Ex tb [ia] IIIC T85°C
IECEx
Ex nA nR [ia] IIC T6 Gc (Gb)
Ex tb [ia] IIIC T85°C Db
Modell FCT3xx-A1... (Transmitter in Zone 1, Sensor in Zone 0, 1 or 2)
Approval
Marking
ATEX
Version II
II 2 (1) G Ex d e ia IIC T6
II 2 (1) D Ex ia tb IIIC T85°C
Version I
II 2 (1) G Ex d e ib [ia] IIC T6 or II 2 (1) G Ex d e [ia] IIC T6
II 2 (1) D Ex ib tb [ia] IIIC T85°C or II 2 (1) D Ex tb [ia] IIIC
T85°C
IECEx
Version II
Ex d e ia IIC T6 Gb (Ga)
Ex ia tb IIIC T85°C Db (Da)
Version I
Ex d e ib [ia Ga] IIC T6 Gb or Ex d e [ia Ga] IIC T6 Gb
Ex ib tb [ia Da] IIIC T85°C Db or Ex tb [ia Da] IIIC T85°C Db
38 - EN CI/FCB300-X1 Rev. C | CoriolisMaster FCB330, FCB350
Comment
-
-
Comment
-
-
Comment
2 passive analog outputs, outputs "ia" / "e", depending on
user wiring.
Active / passive analog outputs, outputs "ib" / "e", depending
on user wiring.
2 passive analog outputs, outputs "ia" / "e", depending on
user wiring.
Active / passive analog outputs, outputs "ib" / "e", depending
on user wiring.