Please avoid narrow passages and elbows for
metal ducts on flexible ducts along the whole
run of the drain pipe.
The drain pipe must remain at least 20 cm
below the drain connection so that the down-
flow of liquids is much easier.
4.3
Accessories connections (PROVER, STEAM
CONDENSER)
Prover connections
To connect the prover with digital control to the
oven, please operate as follows:
1- Remove the back of the oven
2- Remove the metal tongue with pliers (see
the picture)
3- Connect the control cable of the prover to
the power board using the proper connec-
tor (see the picture)
4- Fix the cable fastener your find on the
cable of the prover in the special slit you
find on the bottom of the oven
5- Reassemble the back of the oven
STEAM condenser connection
To connect the steam condenser to the oven,
please operate as follows:
6- Remove the back of the oven;
7- Remove the metal tongue with pliers (see
the picture);
8- Connect the control cable of steam con-
denser to the power board
using the proper connector (see the
picture);
9- Fix the cable fastener your find on the cable
of the steam condenser in
the special slit you find on the bottom of the
oven;
10- Reassemble the back of the oven;
11- Once all the connections are done, the
oven recognizes by itself whether you con-
nected the steam condenser.
4.4
Connection to the gas system