Category
1. Installation 1.1
GB
2. Manual
3. Marking
4. Fill in
24

14. Inspection record

No.
Check:
The correct number of counterweights: 2 on double bracket, 2 on single
bracket, 4 on each double bracket at the bottom of the gate and 4 on the
double bracket at each free end
1.2
The presence of the latch on all double brackets.
1.3
The presence of the latch on the double bracket at each free end.
1.4
The presence of anti-slip pad on single and double brackets.
1.5
Locking of gearwheel of the barriers with the latch
1.6
The presence of the pin (s) on the adjustable guardrails.
1.7
The contact between the lower surface of the gearwheel and the upper
surface of the double bracket tubes.
1.8
On guard trac™ plus guardrail, the contact between the lower surface of the
washer on the central upright and the upper surface of the single bracket tube.
1.9
The presence of the parapet of a minimum height of 150 mm (if not using the
guard trac™ t-b version).
1.10 The presence of the base board and the good condition of the same (if using
the guard trac™ t-b version).
1.11 That the distance between the guardrail and the parapet is a minimum of 50 mm.
1.12 The presence of the clamping wedge and its spring in each single and double
bracket.
1.13 The presence of the counterweight interface between each stacked
counterweight.
1.14 On guard trac™ plus guardrails that the inter-barrier clamps are tightened
1.15 That the gate closes automatically.
1.16 That the 2 handles of the gate are tightened.
1.17 The proper assembly of the gate.
1.18 The good condition of the counterweights.
1.19 That no component is deformed.
1.20 The absence of abnormal corrosion.
2.1
The good legibility of the manual.
2.2
That the inspection sheet is filled in correctly.
3.1
That all markings are legible.
3.2
The presence of the identification plate of the installation completely filled in.
A
Inspector's name.
B
Date of inspection.
C
Inspection OK = YES/NO.
D
Faults eliminated on date.
E
Validation issued on date.
F
Inspector's signature.
G
Next inspection on = E +1 to mention on the identification plate of the
installation