The suction bar can be hung in the recess on the waste
water tank for storage.
Symbols on the device
Fresh water tank drain opening
Waste water tank drain opening
Fresh water tank filling level (50%)
Eyelet point
* Mop holder
Filling system water connection
Waste water tank flushing system water connec-
tion
Brush replacement
* optional
Installation
Unloading
1. Remove the packaging film.
2. Remove the strap.
Strap
1
Board
2
Block
3
Squared timber
4
3. Unscrew the block, squared timber and boards. The
components to be unscrewed are marked in gray in the
illustration.
4. Place a ramp in front of the pallet using the unscrewed
boards and squared timber and fasten with chipboard
screws.
5. Install the batteries if the device was delivered without
batteries (see chapter "Before initial startup/batteries").
6. Drive the device forward and off the pallet (see chapter
"Operation / Driving").
Installing the brushes
1. Installation of the brushes is described in the chapter
"Maintenance work".
Installing the suction bar
1. Pivot both clamping levers upwards.
Suction hose
1
Suction bar suspension
2
Suction bar
3
Clamping lever
4
2. Insert the suction bar in the suction bar mount.
3. Pivot both clamping levers downwards.
Recommended battery packs
Description
Order no.
170 Ah - Main-
4.039-352.7
tenance-free,
AGM
180 Ah - Main-
4.039-354.7
tenance-free,
gel
English
Batteries
Volume
Airflow (m
3
(m
)*
h)**
2.4
1.0
3.8
1.6
3
/
11