Wbe 4120 / Wbe 4120 D / Wbe 4120 Dt - Bosch WBE 4120 Instructions De Réparation

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Calibration menu (WBE 4120 /WBE 4120 D) | WBE 4120 / WBE 4120 D / WBE 4120 DT | 51
5. Read the value on the millimeter scale of the vernier
caliper and enter with the <-> or <+> buttons.
« The value is shown on the right-hand display.
6. Confirm with <+>.
« D-2 appears in the left-hand display
7. Open the vernier caliper as far as possible and hold
in this position.
8. Read the value and enter with the <-> or <+> but-
tons.
9. Confirm with <+> .
« H-1 appears in the left-hand display.
10. Clamp the test wheel (min. 15").
11. Position the vernier caliper against the rim flange.
12. Enter the height of the clamped wheel in inches
with the <-> or <+> buttons.
13. Hold the wheel in this position and confirm with
<+>.
« C-2 appears in the left-hand display.
"
Calibration of the vernier caliper is complete.
Bosch Automotive Service Solutions GmbH
5.2.4

WBE 4120 / WBE 4120 D / WBE 4120 DT

calibration
1. Call up the calibration menu.
2. Press the <MENU> key until C-2 appears on the left-
hand display.
3. Attach a motor vehicle wheel of medium size (e.g.
rim width 5.5", rim diameter 14") and in very good
condition to the flange.
4. Enter the rim data.
5. Close the wheel guard.
« Measurement commences.
« The left-hand display shows C-3, the right-hand
display shows 60.
6. Attach the 60 gr calibrating weight to the rim.
« The new value is displayed on altering the balan-
ce weight.
7. Attach a balance weight of the value entered to the
inner side of the wheel.
8. Close the wheel guard.
« Measurement commences.
« The left-hand display shows C-4.
9. Turn the wheel until the balance weight is in the 12
o'clock position.
10. Remove the balance weight from the inner side
of the wheel and attach it to the outer side (12
o'clock position).
11. Close the wheel guard.
« Measurement commences.
« The left-hand display shows C-5.
12. Turn the wheel until the balance weight is in the 6
o'clock position.
« The calibration angle value is displayed.
13. Press the <SPLIT> key.
"
This completes WBE 4120/ WBE 4120 D calibration.
i
The calibration made is permanently stored automa-
tically.