How To Use The Machine And Surfi Ng Menu; Confi Guration Of The Use; Confi Guration Of The Board; Self-Calibration - Bosch WBE 4120 Instructions De Réparation

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

How to use the machine and surfi ng menu | WBE 4120 / WBE 4120 D / WBE 4120 DT | 43
2.
How to use the machine
and surfing menu
2.1
WBE 4120 /WBE 4120 D
2
4
9 10
Abb. 1:
Control panel
1. Data display
2. Direction LEDs unbalance point
3. Unbalance point (LED)
4. Setting button (-/+ )of the DISTANCE of the circle
5. Setting buttons (-/+ )of the DIAMETER of the circle
6. Setting buttons (-/+ )of the WIDTH of the circle
7. SPLIT button
8. Button to select the unit of measurement for the width or the
diameter of the circle (MM/INCH)
9. Button for the control functions (SET)
10 Setting button for the balancing programme (MODE)
11. STOP button
11. START button
We can divide the balancing machine menu in several
submenus:
$
Configuration of the use
$
Configuration of the board
$

Self-calibration

$

Auto-diagnosis

Press the button "SET" and all the options will be
shown; to confirm, press the button "MM/INCH" by 1.5
second.
Bosch Automotive Service Solutions GmbH
1
3
5
11 12
6
2.1.1
Configuration of the use
Press "SET" until the notice "TOL " is shown.
Left Display Right Display Description
TOL
5
RES
5
UNB
GRA
SND
ON
CAR
ON
7
8
MOT
OFF
2.1.2
Configuration of the board
Press "SET" until the notice "TOL " is shown and then
press "MM/INCH".
Left Display Right Display Description
POT
OFF/ON
2.1.3
Self-calibration
Press "SET" until the notice "CAL " is shown and then
press "MM/INCH".
Left Display Right Display Description
C-1
Left Display Right Display Description
D-1
0 or higher
Left Display Right Display Description
D-2
200
Left Display Right Display Description
H-1
ex.: 14"
Left Display Right Display Description
C-2
C-3
C-4
C-5
It indicates the threshold of the re-
calibration of the balancing ma-
chine
Identification of the unbalance,
rounded off to 5g or real
Selection of the weight
(grams or once)
It indicates the acoustic sound
(beep)
It indicates the possibility to use
the wheel protecting carter for the
launch
It starts the motorcycle programme
It turns on and off the internal au-
tomatic gauge
Memorization of the flange zero
group and shaft
Calibration of the distance
potentiometer: position of rest
Calibration of the distance
potentiometer: position at 20cm
Calibration of the diameter poten-
tiometer
Setting up of the wheel size and
memorization of the unbalance
Setting up of the calibration weight
and launch with the weight inside
Launch with the weight outside
Adjustment of the angle
|
1 695 600 579
2016-08-02
en

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wbe 4120 dWbe 4120 dt

Tabla de contenido