warNINgS!
use alcohol-based disinfectants.
The machine must be cleaned and disinfected every time after use.

7.3.1 ClEaNINg THE PlEXIglaS CovEr

• Wipe using a cloth soaked in potable water or a detergent specially meant for Plexiglas (maximum tempera-
ture 40°C).
• Do not use other types of detergents.
• Dry the cover thoroughly.
7.3.2 CleaNINg The SealINg BaRS
aTTENTIoN!
do not start cleaning operations with the sealing bars hot, as there is danger of burns.
• Clean the upper part of the sealing bar using a clean cloth soaked in potable water.
7.3.3 CleaNINg The vaCUUM ChaMBeR
• Switch the machine off by means of the ON/OFF main switch and disconnect the plug from the mains socket.
• Lift the sealing bar, disconnect the two wires
• Hold the sealbag and pull it upwards
• Insert the safety cap
• Using a cloth soaked in a detergent and/or disinfectant solution,
clean the bottom and sides of the vacuum chamber (fig. 3);
after cleaning, refit the parts by repeating the above operations
in reverse order.
B
B
30
C
.
in the central opening as shown in (fig. 2).
d
C
B
and lift out the sealing bar (fig. 1).
d
fig. 2
fig. 1