Standby Mode; Test Mode; Installation - Roger Technology B70/1DC Instrucciones Y Advertencias Para El Instalador

Ocultar thumbs Ver también para B70/1DC:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 84
will be displayed on the display, which is highlighted:
• by the presence of two decimal points on the first
two left digits (representing the parameter number)
A
• of the letter
in parameters less than 10, to
distinguish them from those of the simplified
version (which are different)
N.B.: The operation can be performed several times,
switching from one mode to another at will.
The table in paragraph 12 contains the parameters
for extended mode.
N.B.: the sequence of parameters for simplified
mode is not the same as that of extended mode,
therefore always refer to the instructions or the
label on the inside of the cover.
5.3

Standby mode

After 30 minutes of inactivity, the control unit enters
standby mode, and the display only indicates a
flashing dot.
The activation of standby automatically resets the
simplified parameters mode.
The mode remains at rest on the display, but the
control unit is always ready to perform commands;
to turn the display back on you have to press one of
the buttons UP,DOWN,+,-.
5.4

TEST mode

This is activated by pressing the TEST button, only if
the motor is stationary; otherwise, the TEST button
performs a STOP command and only the subsequent
operation of the button enables test mode.
The display is as follows:
Name of the active input
(displayed for 5 seconds)
AP
CH
PP
PE
Or
28
safety protection terminal
block number in a state of
alarm (flashing, displayed
until the safety protection
goes back to resting)
Sb = Unlock
highest
15 = ST
priority
13 = COS1
12 = COS2
11 = FT1
10 = FT2
lowest
both limit
FE =
priority
switches
opening
FA =
limit switch
FC =
closing
limit switch
Allows you to visually inspect the activation of the
commands and the safety protections: upon each
of their activations, the control unit briefly activates
the flashing and the Gate Open Light (terminal block
no. 8, SC).
The display indicates:
• the command activated, in fixed letters (on the
left-hand side, for a period of 5 seconds)
• in a flashing number, the safety protection
terminal block in a state of alarm (right part,
displayed as long as the safety protection is in a
state of alarm)
After 10 seconds of inactivity it will return to
commands and safety protections status mode.
To immediately exit test mode just press the TEST
button again.
6

Installation

It is necessary to program the stroke to allow the
correct operation of the control panel.
WARNING! Before proceeding, make sure that:
• The doors are in a fully closed position:
For the program starting from the fully closed
position is important because the control unit
performs a mapping of the absorption of current
along the entire movement, while opening and
then closing. For this reason, if a different path
is detected between opening and closing the
program fails and returns an error message of
AP PL
• The type of installation (left/right) has been
correctly selected.
• The safety protections connected are at rest
and those not present are electrically bridged or
excluded by a special parameter
• If you are trying to access programming mode
but one of the safety protections is in a state of
alarm, you will not be able to do so. The display
changes to test mode and displays the input that
is in a state of alarm and which prevents you from
proceeding.
• If you are trying to access programming mode
but "man present" is enabled(par.
you will not be able to do so and the display will
AP PE
show
.
• The leaf are in the fully closed position, or at least
NOTE:
• Programming is interrupted (with error message
AP PE
) in the following situations:
- The TEST button is pressed.
- One of the safety protections (photocells,
A7 01
),