Commissioning
Solar yield/optimisation
The gross collector area, collector version and climate zone
number must be set correctly in order to achieve maximum
energy savings.
The solar yield displayed is a calculated yield estimate.
Measured values are displayed with the function heat meter (L)
(Accessories WMZ).
Meu item
Setting area: function description
Gross collector
0 ... 500 m
area 1
the area installed in collector array 1. The
solar yield is only displayed if an area > 0 m
is set.
Type collector
Flt-pl. colUse of flat-plate collectors in
array 1
collector array 1
Vacuum tube collector: Use of vacuum tube
collectors in collector array 1
Climate zone
1 ... 90 ... 255: climate zone of the
installation location according to the map
( Fig. 29 at the end of the document).
▶ Search for the location of the system on
the climate zones map and set the
climate zone number.
Min. DHW
Off: DHW reheating via the heat generator
temp.
irrespective of the minimum DHW
temperature
15 ... 45 ... 70 °C: The control system
determines whether solar yield is available
and whether the stored amount of heat is
sufficient to supply DHW. The control system
then reduces the set DHW temperature to be
produced by the heat appliance in
accordance with these two values. If there is
sufficient solar energy yield, there is
therefore no need to reheat the DHW with
the heat generator. If the temperature set
here is not reached, the DHW is reheated by
the heat generator.
40
2
: This function allows you to set
Meu item
Setting area: function description
Solar infl. heat.
Off: Solar influence switched off.
circ. 1
– 1 ... – 5 K: influence of solar on the set
room temperature: at a high value, the flow
temperature of the heating curve is reduced
at a correspondingly greater rate in order to
achieve greater passive solar energy input
through the building's windows. At the same
time this reduces a temperature overshoot in
the building and increases the comfort level.
2
Reset solar
Yes | No: Resets the solar yield to zero.
yield
Reset solar
Yes | No: Resets the solar optimisation
optimisation
calibration and restarts it. The settings for
Solar yield/optimisation remain unchanged.
Set temp.
Off: controls to achieve a constant
Match-F.
temperature differential between collector
and cylinder (Match-Flow).
35 ... 45 ... 60 °C: "Match-Flow" (only in
combination with speed control) is used to
quickly heat the top part of the cylinder to
45 °C, for example, in order to prevent the
potable water being reheated by the heat
generator.
Glycol content 0 ... 45 ... 50 %: to obtain accurate readings
from the heat meter, the glycol content of the
solar thermal fluid must be specified.
Table 10 Solar yield/optimisation
Transfer
Meu item
Setting area: function description
Transfer
6 ... 10 ... 20 K: if the differential set here
switch-on diff.
between cylinder 1 and cylinder 3 is
exceeded and all switch-on conditions have
been met, the transfer pump is on.
Transfer
3 ... 5 ... 17 K: if the differential between
switch-off diff.
cylinder 1 and cylinder 3 falls below the
value set here, the transfer pump is off.
Table 11 Transfer
Increase Solar infl. heat. circ. 1 ( – 5 K =
max. influence) if the heating circuit
heats rooms that have large south-facing
windows.
Do not increase Solar infl. heat. circ. 1 if
the heating circuit heats rooms that have
small areas of north-facing windows.
MS 100 – 6721830547 (2020/12)