Selecting the type of photocell test on input FT1
This parameter is visible if
If the photocell test is enabled, the control unit will check the photocells connected to input FT1 are working properly.
Selecting the type of photocell test on input FT2
This parameter is visible if
If the photocell test is enabled, the control unit will check the photocells connected to input FT2 are working properly.
Photocell test disabled.
Photocell test enabled on opening ONLY.
Photocell test enabled on closure ONLY.
Photocell test enabled on both opening and closure.
Method and management of SMARTY 5R5- SMARTY 7R automation reversibility
This parameter is visible ONLY if
NOTE: Even though it is a REVERSIBLE unit, the motor is equipped with a lock release system.
The SMARTY 5R5/7R motor is always REVERSIBLE.
The gate leaf may be moved manually in either direction (open or close) without unlocking the motor, with or without
mains power, when the motor is not running.
WARNING: when the control unit is powered, consider the possibility of an electric lock.
The SMARTY 5R5/7R motor is REVERSIBLE ONLY when the controller is NOT powered.
sing force of the motor is counteracted
If the unit is not powered, the gate leaf can be moved manually without releasing the motor (in both opening and
closure).
WARNING
IMPORTANT! Always disconnect from mains power and (if applicable) battery power before disconnecting the terminal
board of the motor from the controller or disconnecting any of the motor wires.

Setting motor stop distance

Select number of motors installed
N.B.:
(see chapter 11).
1 motor.
2 motors. IMPORTANT
Enabling absolute encoder (SMARTY Series automation systems only)
Attention: the parameter
REVERSIBLE motor.
NB: the position data request message
PROG key until
Attention: SMARTY motors with SMARTY/EMA installed must not be installed to open the door towards the outside
Disabled.
Enabled. Perform or repeat the acquisition procedure to acquire the parameters relative to the installation. N.B: see
chapter 12 for more information on the absolute encoder.
Sensing edge NOT INSTALLED.
NC contact (normally closed). The gate reverses only when opening.
Contact with 8k2 resistor. The gate reverses only when opening.
NC contact (normally closed). The gate always reverses.
Contact with 8k2 resistor. The gate always reverses.
Management of two 8k2 sensitive edges connected in parallel (total resistance 4k1). The gate reverses only when
opening.
74
N.C.
8k2
or
is set.
or
is set.
or
must be set and SMARTY/EMA installed for all applications with the SMARTY
appears on the display, then repeat the acquisition procedure (see chapter 11.2).
COS1
8k2
8k2
.
8k2
8k2