Beep signal
Vibration
signal
1x short
1x short
2x short
2x short
3x short
3x short

14.2.2 Warnings/error signals

Error during use
Beep signal
5x long
10x long
Additional action per­
formed
Weight taken off prosthetic
leg and leg kept still for 1
second
Weight taken off prosthetic
leg and leg kept still for 1
second
Weight taken off prosthetic
leg and leg kept still for 1
second
Vibration signal
1 x long at intervals of
approx. 5 seconds (if
mute mode (silent
mode) is activated,
this signal is not gen­
erated)
3x long
5x long
10x long
Event
Switching to basic mode
(mode 1) carried out.
Switching to MyMode 1 (mode 2)
carried out.
Switching to MyMode 2 (mode 3)
carried out.
Event
Overheated hydraulic
unit
Battery charge level
under 25%
Battery charge level
under 10%
Medium error:
e.g. a sensor is not
operational
Switch to safety
mode (see Page 80).
Battery charge level
5%
After the beep and
vibration signal, the
product switches to
empty battery mode
and then switches
off.
Required action
Reduce activity.
Charge battery soon.
Remaining operating time
approx. 24 hours
Charge battery soon
Remaining operating time
approx. 6 hours
Restricted walking pos­
sible. The change in flex­
ion resistance has to be
noted.
The product must be
inspected immediately by
a prosthetist.
Charge the battery.