en - Original instructions
2.
Notify our distributor within eight days of the
delivery date, if the product bears visible
signs of damage.
Unpack the unit
1.
Follow applicable step:
–
If the unit is packed in a carton, then
remove the staples and open the
carton.
–
If the unit is packed in a wooden crate,
then open the cover while paying
attention to the nails and straps.
2.
Remove the securing screws or the straps
from the wooden base.
2.1.1 Inspect the unit
1.
Remove packing materials from the product.
Dispose of all packing materials in
accordance with local regulations.
2.
Inspect the product to determine if any parts
have been damaged or are missing.
3.
If applicable, unfasten the product by
removing any screws, bolts, or straps.
4.
Contact the local sales representative if there
is any issue.
Transportation guidelines
2.2
Precautions
WARNING:
Observe accident prevention
regulations in force.
Crush hazard. The unit and the
components can be heavy. Use
proper lifting methods and wear
steel-toed shoes at all times.
Check the gross weight that is indicated on the
package in order to select proper lifting equipment.
Position and fastening
Keep the pump / pump unit in the same position in
which it was supplied from the factory. Make sure
that the pump or pump unit is securely fastened
during transportation and cannot roll or fall over.
WARNING:
Do not use eyebolts screwed on
the motor for handling the whole
electric pump unit.
Do not use the shaft end of the
pump or of the motor to handle the
pump, the motor or the unit.
Eyebolts screwed onto the motor may be
exclusively used to handle the individual
motor or, in case of a not balanced
distribution of weights, to partially lift the unit
vertically starting from a horizontal
displacement.
Pump unit must always be fixed and transported as
shown in
Figure
4.
Unit without motor
WARNING:
According to Machinery directive
2006/42/EC, a pump and motor that are
purchased separately and then coupled
16
together result in a new machine. The
person making the coupling is
responsible for all safety aspects of the
combined unit and for CE-marking.
2.3 Storage guidelines
Storage location
The product must be stored in a covered and dry
location free from heat, dirt, and vibrations.
NOTICE:
Protect the product against humidity, heat
sources, and mechanical damage.
Do not place heavy weights on the packed
product.
2.3.1 Long-term storage
If the unit is stored for more than 6 months, these
requirements apply:
Store in a covered and dry location.
Store the unit free from heat, dirt, and
vibrations.
Rotate the shaft by hand several times at
least every three months.
Refer to the drive unit and coupling manufacturers
for their long-term storage procedures.
For questions about possible long-term storage
treatment services, please contact your local sales
and service representative.
Ambient temperature
The product must be stored at an ambient
temperature from -5°C to +40°C (23°F to 104°F).
3 Product Description
3.1 Pump description
The pump is a multistage centrifugal ring section
pump with suction impeller for low NPSH value.
The pump can be horizontal or vertical, close-
coupled to standard electric motors.
The pump can be used for handling:
Cold or warm water
Clean liquids
Clean or aggressive fluids which are not
chemically or mechanically aggressive to
the pump materials
The product can be supplied as a pump unit
(pump and electric motor) or only as a pump.
NOTICE:
If you have purchased a pump without motor,
make sure that the motor is suitable for coupling
to the pump.
Intended use
The pump is suitable for:
Water supply and water treatment
Cooling and hot water supply in industries
and building services
Irrigation and sprinkler systems
Heating systems
Fire-fighting applications