en
38 | EPS 205 | Maintenance
8.2.7
Replacing intake filter in test oil tank
!
The intake filter contains oil-based substances and
substances which are a hazard to water. It must
be disposed of in accordance with the applicable
regulations.
!
When changing the suction filter for the first time,
the customer service personnel has to check
the connection between the cooling coil and the
screwed fitting on the test oil tank for leaks.
i
Replace the intake filter and assemble the EPS 205
before re-filling with test oil.
Procedure:
1. Drain the test oil from the tank before replacing the
intake filter (see Sec. 8.2.6, steps 1 to 8).
2. Unscrew the right housing cover bolts.
3. Detach the housing cover.
4. Unscrew the bolts (4x) (Fig. 43, item 3) for the jet
chamber unit.
5. Raise the jet chamber unit (Fig. 43, item 1).
6. Disconnect the hose (Fig. 43, item 5) from the plug-
in connection (Fig. 43, item 4). This involves press-
ing the ring of the plug-in connection to the rear.
7. Detach the two hoses at the quick-release
couplings (Fig. 43, item 6).
8. Disconnect the connecting cable for the ring lamp at
the connector (Fig. 43, item 7).
9. Unscrew the ground cable at the jet chamber unit
(Fig. 43, item 2).
10. Lift the jet chamber unit completely off the EPS 205
and set it down next to the EPS 205.
|
1 689 989 186
2017-10-27
7
6
3
5
Abb. 43: Removing jet chamber unit
1 Jet chamber unit
2 Ground cable
3 Bolts
4 Plug-in connection
5 Hose
6 Quick-release couplings
7 Ring lamp connector
1
2
3
5
4
Robert Bosch GmbH