Descargar Imprimir esta página

Corghi ET 1450 Manual De Uso página 127

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

E 1 C
Sensitivity not calibrated in CAR environment.
Perform the sensitivity calibration procedure.
E 1 C
Sensitivity not calibrated in TRUCK environment.
Perform the sensitivity calibration procedure.
E 2
Error condition during sensitivity calibration.
Repeat sensitivity calibration paying attention to the first spin, which must
be performed with the wheel as in the successive spins.
Take particular care NOT to knock the machine during calibration.
E 3 I/E 2/3 Error condition at the end of sensitivity calibration. Repeat the calibration, if
the message persists perform the following checks:
Correct sensitivity calibration procedure;
Correct fastening and position of the calibration weight;
Geometry of the wheel used.
E 4
Error condition relative to calibration on inner probe.
Contact technical support service.
E 6
Error condition when executing optimisation programme.
Repeat the procedure from the beginning.
E 27
Excessive braking time. If the problem persists, contact the technical sup-
port centre.
E 28
Encoder counting error. If the error occurs frequently, call in the technical
support centre.
E 30
Wheel spin device failure. Switch off the machine and call in the technical
support centre.
E 32
The wheel balancer has been jolted during the reading phase. Repeat the
wheel spin.
E F0
Error in reading the 0 notch.
Spd Hi
Spin speed too high.
Allow the wheel to slow down until the message disappears.
E Rot
Wheel spin in anticlockwise direction.
Apply the brake and restart the spin correctly in the clockwise direction.
- This message indicates the valve of the wheel that must be brought to
OP.1
the 12 o'clock position during phases 1 and 5 of optimisation (OPt)
- This message indicates that the position of the valve must be moved 180°
OP.2 180
with respect to the previous position (12 o'clock)
- This message is displayed when the improvement obtained by optimi-
sation is not sufficient
Out 2
- Press the
the optimisation phase.
Operator's Manual ET 1450
– E – Error messages
OTHER MESSAGES
key to exit the program or the
UK
key to continue
127

Publicidad

loading