Descargar Imprimir esta página

Grundfos SP Serie Instrucciones De Instalación Y Funcionamiento página 23

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 127
Motor type
PVC windings
MMS10000
PE/PA windings
PVC windings
MMS12000
PE/PA windings
Number of starts
Grundfos recommends mini-
mum 1 per year.
Maximum 2 per hour.
Maximum 20 per day.
Grundfos recommends mini-
mum 1 per year.
Maximum 6 per hour.
Maximum 50 per day.
Grundfos recommends mini-
mum 1 per year.
Maximum 2 per hour.
Maximum 15 per day.
Grundfos recommends mini-
mum 1 per year.
Maximum 5 per hour.
Maximum 40 per day.
10. Service
All pumps are easy to service.
Service kits and service tools are available from Grundfos.
The pumps can be serviced at a Grundfos service centre.
If Grundfos is requested to service the pump, Grundfos must be
contacted with details about the pumped liquid, etc. before the
pump is returned for service. Otherwise Grundfos can refuse to
accept the pump for service.
Possible costs of returning the pump are paid by the customer.
Additional service documentation including service videos are
available in Grundfos Product Center > http://product-
selection.grundfos.com/.
DANGER
Electric shock
Death or serious personal injury
Switch off the power supply before starting any work
on the product.
Make sure that the power supply cannot be accidental-
ly switched on.
DANGER
Toxic or radio active liquid
Death or serious personal injury
If a pump has been used for a liquid which is injurious
to health or toxic, the pump will be classified as conta-
minated.
WARNING
Sharp element
Death or serious personal injury
For service - see service instructions. Must be per-
formed by qualified persons.
10.1 SPE
The following is only valid for SPE pump sets.
DANGER
Magnetic field
Death or serious personal injury
Do not handle the rotor if having a pacemaker.
DANGER
Crushing of hands
Death or serious personal injury
Keep the rotor surroundings free of magnetic objects
and be careful when placing the rotor on a magnetic
surface.
DANGER
Electric shock
Death or serious personal injury
Make sure that motor cable ends are not live before
starting work on the product.
Make sure that the power supply cannot be accidental-
ly switched on.
In case of unintended flow of water through a non-energized pump
there is a risk that the moving parts of the pump and the motor will
start rotating, thereby generating voltage over the terminals. The
size of the voltage depends on the speed of rotation. Due to this the
motor terminals must be considered as live until proven otherwise.
23

Publicidad

loading