Descargar Imprimir esta página

HPA-Faip M 624 2V FS Uso Y Mantenimiento página 44

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 52
If they are not correctly positioned, deflate, break the bead, lubricate and turn the tyre on
the rim.
Repeat the mounting procedure and check again.
If the problem persists, demount the tyre and check compatibility with the rim. Make
sure that there is no deformation of the tyre and/or the rim, clean and lubricate them
thoroughly, then mount the tyre once more.
If the problem persists further, consult the manufacturers of the rim and tyre.
WARNING
For technical characteristics, attention notices, maintenance and all other information
regarding the air tank, refer to the air tank user and maintenance manual supplied with
the machine documentation.
TROUBLE-SHOOTING
The following list indicates a series of possible faults that the user can remedy if the cause is
among the various alternatives suggested.
In all other cases it will be necessary to request the intervention of your nearest SIMPESFAIP
service centre.
When you press the table top rotation pedal the fuses blow
Power cord conductor shorting to ground
- Check the wiring
Motor shorted
- Renew the fuses
- Renew the motor
Rotation control pedal fails to return to the central position
Control spring broken
- Renew the spring
Bead breaker pedal and table top pedal do not return to home position
Control spring broken
- Renew the spring
No oil in lubricator
- Top up lubricator with SAE20 non-detergent oil.
Air leak inside the machine
Air leak from bead breaker cock
- Renew the cock
- Renew bead breaker cylinder
Air leak from the table top cock
- Renew table top cylinder
- Renew swivel connector
Bead breaker cylinder lacks force, fails to break beads and leaks air
Silencer plugged
- Renew silencer
Cylinder seals worn
- Renew seals
- Renew bead breaker cylinder
19

Publicidad

loading

Productos relacionados para HPA-Faip M 624 2V FS

Este manual también es adecuado para:

M 624M 624 fsM 624 2v