When the machine is disconnected from the air system, the devices bearing the above
plate may remain pressurized.
The FRL unit (filter, regulator and lubricator) is installed to filter the air, regulate its pressure and
lubricate it.
The FRL unit withstands a maximum input pressure of 18 bar and has a regulation range from
0.5 to 10 bar. The setting can be modified by pulling the knob to the OUT position and turning it;
after adjusting, return the knob to the locked position by pushing it down (fig. 24a).
The lubricating flow-rate is adjusted by turning the screw on the element "L", (fig. 24b); normally
the unit is preset at a pressure of 10 Bar, with lubricant having viscosity SAE20, so that one
drop of lubricant is dispensed every 4 times the bead-breaker is operated (check through the
transparent cup).
Before carrying out any maintenance operation or topping up with lubricant, disconnect
the machine from the compressed air supply line.
Check the lubricant level periodically through the windows provided and top up as shown in fig.
24c. Top up only with SAE20 non detergent oil to a total quantity of 50 cc.
The FR filter regulator unit is equipped with an automatic system for drainage of the
condensation water, so in normal conditions it does not require any particular maintenance.
However, the water may be drained by hand at any time (fig. 24d).
Normally it is not necessary to remove the cups, but this may be necessary after long periods out
of use; if the cup cannot be removed with the hands only, use the spanner provided (fig. 24e).
Clean with dry cloth. Avoid contact with solvents.
Keep the work area clean.
Do not clean the machine with compressed air or jets of water.
When cleaning the area avoid raising dust as far as possible.
If the machine is to be scrapped, remove all electrical, electronic, plastic and metal parts and
dispose of them separately in accordance with current provisions as prescribed by law.
Following disposal procedure shall be exclusively applied to the machines having the crossed-
out bin symbol on their data plate
This product may contain substances that can be hazardous to the environment or to human
health if it is not disposed of properly.
We therefore provide you with the following information to prevent releases of these substances
and to improve the use of natural resources.
DANGER
DANGER
ATTENTION
DEMOLITION
ENVIRONMENTAL INFORMATION