HANDLING AND INSTALLATION
WARNING: Air inlets are required in
the room where the appliance is installed to
ensure a proper operation of the appliance
and to exchange the air in the room .
WARNING: The air inlets should be of
appropriate size, protected by gratings, and
placed so that they cannot be obstructed .
Grease the 2 O-rings ( A and B) mounted on
1)
the drain pipe (C) .
Insert the flange (D) .
2)
Insert the cock (E) up to the stop on the drain
3)
pipe (C) .
Place the cock (E) vertically and block the 3
4)
M6 dowels (F) .
Place the flange (D) up to the stop on the
5)
front panel .
Provide a suitable drainage system (G) un-
6)
derneath the drain tap (E) .
Adjust the floor-mounted feet (A) to level the
appliance .
3413940_inst_GB