Broadcast Commands
General
Broadcast commands are not sent to any particular inverter in the system. A broadcast
command is either carried out by the interface unit of the first inverter that receives the
command or it enables data queries from the interface unit of several inverters.
Broadcast Com-
Value
mands
0x01
0x03
0x04
0x05
0x06
Available for:
0x01 - Get versi-
on
Up to 100 INV
via RS 232
X
The IFC type (e.g.: 0x03 - Virtual Interface Card) and the associated software version
(e.g.: 0x01 - 0x00 - 0x00) is sent as a reply to the command.
Query:
Start
Response:
Start Length Device / Option Number Command IFC type
IFC types:
Value
0x01
0x02
0x03
Command
Get version (software version of interface unit)
Get date time
Get active inverter (number of active inverters)
Get active sensor cards (number of active sensor cards)
Get Solar Net status (network status)
1 INV via RS 232
(IFC easy)
X
Length Device / Option Number
0x00
0x00
0x04
0x00
Device / Option
up to 100 INV via RS 232 (interface card / box)
1 INV via RS 232 (Interface Card easy)
up to 100 INV via RS 422 (virtual interface card Fronius IG Plus,
Fronius IG TL)
Up to 100 INV
via RS 422
(IG Plus/CL)
X
Command Checksum
0x01
Version information
0x01
(3 bytes; major, minor,
release)
52
Up to 100 INV
via RS 422 (IG TL)
X
Checksum