The '0x07 - Set error sending' command is used to activate or deactivate the automatic
0x07 - Set error
display of error messages for a system with up to 100 inverters via an RS 422 interface.
sending (active
(If deactivated, the only errors shown are those that have triggered an SMS in the
error forwarding
Fronius DATCOM):
inverter)
-
-
The selected option continues to be saved.
Important To deactivate the display of error messages automatically, enter '0x00' in the
Error code byte.
Query:
Start Length
An inverter that receives this query and its network number is on the list
-
-
-
The sender can now determine which devices have successfully received the frame by
analysing the inverter number field:
Inverter number 0xFF = inverter has carried out the command
Inverter number not 0xFF = inverter has not carried out the command
Enter error code '0x55' in the byte
Enter the IG numbers of the inverters that should carry out the command in the
inverter number byte. Several inverters can be activated/deactivated simultaneously.
Device / Option Number Command Error code
0x02-0x65 0x00
carries out the corresponding action
overwrites its network number with 0xFF
and forwards the frame
0x07
0x55
62
Inverter numbers
Checksum