Measured value
Value Command / Query
queries
0x27 Get maximum AC voltage - TOTAL
(continued)
0x28 Get minimum AC voltage - TOTAL
0x29 Get maximum DC voltage - TOTAL
0x2A Get operating hours - TOTAL
0x2B Get phase current for phase 1
0x2C Get phase current for phase 2
0x2D Get phase current for phase 3
0x2E Get phase voltage for phase 1
0x2F Get phase voltage for phase 2
0x30 Get phase voltage for phase 3
0x31 Ambient temperature
0x32 Front left fan rotation speed
0x33 Front right fan rotation speed
0x34 Rear left fan rotation speed
0x35 Rear right fan rotation speed
0x36 Get energy total ex
0x37 Get inverter status-
(1)
Details about
Value Command /
measured value
queries 0x11 -
0x11 Get energy
0x13
0x12 Get energy
0x13 Get energy
(max. total AC voltage)
(min. total AC voltage)
(max. total DC voltage)
(total operating hours)
(phase current of phase 1)
(phase current of phase 2)
(phase current of phase 3)
(phase voltage of phase 1)
(phase voltage of phase 2)
(phase voltage of phase 3)
(ambient temperature)
(rotational speed of front left fan)
(rotational speed of front right fan)
(rotational speed of rear left fan)
(rotational speed of rear right fan)
(total (Wh resolution)
generated energy)
(inverter status)
Currency, depends on the settings specified for the device
Exponent
Query
Fronius IG IG Plus, Fronius CL
10
(KWh)
3
- TOTAL
10
(KWh)
3
- DAY
10
(KWh)
3
- YEAR
Unit
V
V
V
Minutes
A
A
A
V
V
V
°C
rpm
rpm
rpm
rpm
Wh / kWh
-
Exponent Fronius
10
(Wh) for 0 - 999,
0
then 10
(KWh)
3
10
(Wh) for 0 - 999,
0
then 10
(KWh)
3
10
(Wh) for 0 - 999,
0
then 10
(KWh)
3
41
Data type
unsigned
unsigned
unsigned
unsigned
unsigned
unsigned
unsigned
unsigned
unsigned
unsigned
signed
unsigned
unsigned
unsigned
unsigned
unsigned
Exponent Fronius TL
10
(Wh) for 0 - 65535,
0
then 10
(KWh)
3
10
(Wh) for 0 - 65535,
0
then 10
(KWh)
3
10
(Wh) for 0 - 65535,
0
then 10
(KWh)
3