0X05 - Get Active Sensor Cards; 0X06 - Get Solar Net Status - Fronius IG-TL Serie Manual De Instrucciones

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 223
0x05 - Get active
Available for:
sensor cards
Up to 100 INV
via RS 232
X
The '0x05 - Get active sensor cards' command shows which sensor cards are active in a
Solar Net system. One byte is output for each active sensor card. The output byte
corresponds to the number of the sensor card configured using the BCD switch.
The maximum size of the data field is 10 bytes.
Query:
Start Length Device / Option Number
Response:
Start Length Device / Option Number Command
0x06 - Get Solar
Available for:
Net status
Up to 100 INV
via RS 232
X
The '0x06 - Get Solar Net status' command displays the current network status of the
interface card.
Important The 'Get Solar Net status' command displays the current network status of
only the interface card, not of the complete system.
The Solar Net status of the interface card is output as a 1-byte value of the 'unsigned'
char data type.
One possible cause of an error message when querying the Solar Net status is an open
Solar Net ring. An open Solar Net ring can be caused by a faulty network cable or a
missing terminating plug.
An open Solar Net ring is indicated by the red LED on the datalogger.
Query:
Start Length Device / Option
Response:
Start Length Device / Option Number
1 INV via RS 232
(IFC easy)
-
0x00
0x00
n
0x00
1 INV via RS 232
(IFC easy)
-
Number
0x00
0x00
0x01
0x00
ignore
Up to 100 INV
via RS 422
(IG Plus/CL)
-
Command
Checksum
0x05
Active sensor card
0x05
(0 -10 bytes)
Up to 100 INV
via RS 422
(IG Plus/CL)
-
Command Checksum
0x06
Command Solar Net status
0x06
(1 byte,
1 = Solar Net OK
0 = Solar Net Error)
54
Up to 100 INV
via RS 422 (IG-TL)
-
Checksum
Up to 100 INV
via RS 422 (IG TL)
-
Checksum