Descargar Imprimir esta página

Active Error Forwarding - Fronius IG-TL Serie Manual De Instrucciones

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 223

Active Error Forwarding

0x0D - Set error
The '0x0D - Set error forwarding' command is used to activate or deactivate the auto-
forwarding
matic display of error messages for a system with up to 100 inverters via an RS 232
(active error
interface (Interface Card) and a system with 1 inverter via an RS 232 interface (Interface
forwarding
Card easy). If deactivated, the only errors shown are those that have triggered an SMS
Interface Card,
in the Fronius DATCOM. The selected option is saved permanently.
Interface Card
easy)
Interface Card:
-
-
Interface Card easy:
-
-
Important To deactivate the display of error messages automatically, enter '0x00' in the
Error code byte.
Query:
Start Length Device / Option Number Command Extra
Response:
Start
Enter error code '0x55' in the byte
Enter the respective day in the Extra byte (e.g.: 16 = 0x10 for 16.07.2009)
Enter error code '0x55' in the byte
Enter '0x02' in the Extra byte
0x02
0x00
Length Device / Option Number
0x01
0x00
Error code
0x0D
0x02
0x55
Command Error code Checksum
0x0D
0x55
61
Checksum

Publicidad

loading