Automatic Reclosing After The Pause Time; Extended Operation Mode - Roger Technology B70/1DC Instrucciones Y Advertencias Para El Instalador

Ocultar thumbs Ver también para B70/1DC:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 84
by connecting their positive terminals to the SC
terminal (Figure 8). Set the parameter
a804
(or
if you want to also include the photo-
test). In this way, when the door are fully open or fully
closed and the battery is delivering current, power
is cut to the devices connected to the SC terminal
The battery operation is shown on the display by the
Ba TT
message
and by the occasional activation
of the flashing light (saving consumption). At the
drop of the battery voltage the speed of the door
decrease When the battery voltage drops below
a minimum value for its integrity, the commands
given to the control panel are no longer performed,
and the display shows
function is restored when the mains voltage is back
or in case of possible recovery of battery power,
during the forced inactivity.
If the power failure occurs during the travel, a stop
of engine can be generated, with automatic resume
parameter number
selectable values
A2 00

Automatic reclosing after the pause time

00
OFF (doesn't automatically relock)
01
15
NUMBER of reclosure attempts (interrupted by photocell) before finally staying open
-
99
try to close without limitation to the number of attempts
NOTE: parameter
To enable automatic reclosing you must set this parameter to a different number from
parameter the value
01
between
setting the value
would re-open but would no longer close (only performs one reclosing attempt).
NOTA: the value of the parameter
49
has a maximum value equal to that of parameter
a803
BT L0
(Low battery); the
A2 00
01
-
1-
in simple mode.
99
will it always reclose after the pause time. However, if you set a number
15
and
, is the maximum number of attempts at reclosing carried out. For example, by
01
, f a person crosses the ray of the reversal photocells when reclosing, the wing
of motion after a stabilization break (2").
12

Extended operation mode

N.B.: if you are only using the simplified mode the
value of the invisible parameters - for a control
unit leaving the factory, or after a reset of the
standard parameters - this is the one shown next to
the parameter, and is considered to be of greater
usefulness in installations.
WARNING! Depending on the selected mode,
some parameters may not be displayed, as they do
not relate to the installation.
The table for the extended mode parameters is
below. The standard production value is next to the
parameter number.
standard
production value
Parameter description
00
function associated with the value 00
15
function associated with values from 01 to 15
49
is subordinate to that selected for parameter
a2
.
00
; only by
a2
; parameter
31

Publicidad

Tabla de contenido
loading

Tabla de contenido