Analog Load Cell Scale Base; Idnet  Scale Base; Sicspro Scale Base; Com1 Serial Port - Mettler Toledo IND560x Manual De Instalación

Ocultar thumbs Ver también para IND560x:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 93
pack. The IND560x-PAB can only be used with revision D or higher of the analog version of the
main board. Refer to Appendix A, Installation for more information regarding the IND560x-PAB.
1.11.1.

Analog Load Cell Scale Base

The IND560x can provide power for up to an 87 ohm load (four 350-ohm analog load cells). A
jumper permits configuration for 2mV or 3mV load cells; the 3mV position is selected at the factory.
A removable terminal strip is provided for the load cell connection.
1.11.2.
IDNet
The IND560x supports the newer T-Brick Ex T4 style of intrinsically safe high-precision base
through the main board IDNet port. This port provides the power and communication required to
operate this newer style base.
1.11.3.

SICSpro Scale Base

The IND560x supports a SICSpro platform through the main board's SICSpro port. The SICSpro
interface supports PBK9 and PFK9 high-precision platforms with MPXI load cells. The IND560x
SICSpro interface supports only those SICSpro platforms that include the Advanced Setup Mode
(ASM).
1.11.4.

COM1 Serial Port

The main board also contains the COM1 serial port that provides intrinsically safe RS-232
communication. The port is bidirectional and can be configured and used for various functions
such as demand output, SICS host communications, continuous output, ASCII command input (C,
T, P, Z), ASCII character input, report printing, Shared Data Server access, or connection with the
InSite PC Tool.
64061929
|
11
|
07/2017
Note: The revision level is not indicated on the IND560x main board. Revision D (and higher)
main boards can be identified by the presence of the W3 jumper. If a main board has a W3
main jumper, it is at least revision D or higher. If the W3 jumper is not present, the main board
is lower than revision D and cannot be used with the IND560x-PAB.
Note: When installed, the IND560x-PAB will cover the mV jumper. Please take this into
consideration during installation of the IND560x analog model.
Scale Base
Note: The older PIK Ex module is not supported by the IND560x.
Note: IND560x IDNet terminals cannot be used with the IND560x-PAB and external NiMH
battery pack.
Note: The approval entity parameters for the COM1 serial port must be checked for compatibility
with those of the remote device when making direct connections to this port inside the
hazardous area. When connecting COM1 to a peripheral in the safe area, a barrier will be
required to properly protect the port and ensure safety of the system. Compare entity values of
the IND560x terminal and the barrier to confirm safe compatibility before connecting.
METTLER TOLEDO IND560x Installation Manual
1-13

Publicidad

Tabla de contenido
loading

Tabla de contenido