3.12.2.

Sealing the Harsh Enclosure

3.12.2.1.
United States and Canadian Sealing
To seal the harsh enclosure follow these steps:
1. Ensure that the appropriate approval region has been selected in setup under Scale > Type >
2. Place the terminal with the front cover face-down on a soft, flat surface.
3. Ensure the gasket is in the correct position.
4. Align the holes in the rear housing with the threaded holes in the front cover.
5. Install the through-hole screws provided in the sealing kit – they replace two or three of the
6. Locate seven of the ten screws originally securing the cover and reinstall them by turning
7. Torque all screws to 1.5 Nm.
8. Thread the wire cable and plastic seal through the hole in each new screw.
9. Remove any remaining slack in the wire cable.
10. Thread the end of the wire cable through the plastic seal and snap the seal shut. Cut off any
3.12.2.2.
European Sealing
To seal the harsh enclosure follow these steps:
1. Ensure that the appropriate approval region has been selected in setup at Scale > Type >
2. Place the terminal with the front cover face-down on a soft, flat surface.
3. Ensure the gasket is in the correct position.
4. Align the holes in the rear housing with the threaded holes in the front cover.
5. Locate nine of the ten screws originally securing the cover and reinstall them by turning
6. In the remaining 10
7. Torque all screws to 1.5 Nm.
8. Place an appropriate paper mark over the sealing sleeve/screw combination.
3-44
METTLER TOLEDO IND560x Installation Manual
Approval, and that the Metrology security switch SW1-1 is in the "ON" position.
screws used to attach the front panel to the harsh enclosure. The U.S. and Europe require 2-
point external sealing. Canada requires 3-point external sealing.
clockwise.
excess wire.
Approval, and that the Metrology security switch SW1-1 is in the "ON" position.
clockwise.
th
spot, take the screw from the sealing kit and insert it through the sealing
sleeve found in the sealing kit. Install the sealing sleeve/screw combination.
64061929
|