Commands Top603H; Outputs And Accessories - entrematic Ditec TOP603H Manuale Tecnico

Ocultar thumbs Ver también para Ditec TOP603H:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 196
13.2

Commands TOP603H

Command
18
19
NO
STEP-BY-STEP
OPENING
NO
STEP-BY-STEP
OPENING
NC
STOP
NC
REVERSAL
SAFETY
13.3
Outputs and accessories TOP603H
Output
Value - Accessories
24 V
24 V
continuous
230 V~ / 25W
max 1.6A
max 230 V~ / 60W
1
2
GOL148REA
20
21
WARNING: make a jumper for all unused NC contacts.
i
Keep the YELLOW and/or GREEN connectors if accessories are to be connected.
Function
The closure of the contact activates a sequential opening or
closing operation: opening-stop-closing-stop.
With automatic closure enabled (parameter b4), the closure of
the contact activates an opening operation.
The closure of the contact activates a sequential opening or
closing operation: opening-stop-closing-stop.
With automatic closure enabled (parameter b4), the closure of
the contact activates an opening operation.
The opening of the safety contact causes the current move-
ment to stop, and the automatic closure is disabled.
The opening of the safety contact triggers a reversal of the
movement (reopening) during the closing operation, and the
flashing of the courtesy light.
After the 3rd consecutive reversed movement, the automatic
closure is disabled (if active) and the courtesy light flashes
for about 10 min.
Power supply to accessories.
/ 0.3A for 2s
The maximum continuous absorption refers to all the accessories
/ 0.08A
installed. Yellow wire (+24V) and black wire (-0V) with TOP905CAB2.
Flashing light (with TOP905AC).
LAMP
Activated during opening and closing operations.
Electric lock (with TOP905AC).
Activated for 1s at each start (even with the door open).
Courtesy light.
Activated for 120s at the end of every operation.
An additional E14 courtesy light can be connected (in parallel) - max
60W or equivalent.
DO NOT CONNECT fluorescent tubular lamps.
NB: some energy-saving lamps may interfere with the radio signal.
Antenna
Connect the supplied antenna wire (345mm), or alternatively the
GOL148REA antenna, using an RG58 coaxial cable.
Description
Description
74

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ditec top903h

Tabla de contenido