24. Parameters TOP903H
Menu
Deceleration distance on opening
000 = 0cm
001 = 7cm
002 = 14cm
...
009 = 63cm
Deceleration distance on closing
000 = 0cm
001 = 7cm
002 = 14cm
...
009 = 63cm
Deceleration speed on closing (mm/s)
000 = 50mm/s
009 = 140mm/s
Disengagement on the closing stop
000 = disabled
001 = enabled
Direction selection
000 = disabled
001 = enabled
This setting is only possible if the EMERGENCY STOP connec-
tor (1, green) is disconnected.
Thrust adjustment on obstacles during opening
000 - minimum thrust
009 - maximum thrust
Thrust adjustment on obstacles during closing
000 - minimum thrust
009 - maximum thrust
NB: after detecting an obstacle during a closing operation, the
automation reverses its stroke for about 800mm. Automatic
closure is disabled (if active) and the courtesy light flashes
for about 10 min.
WARNING: to ensure the closing thrust force values return
within the limits established by Standard EN12453, you must
set a value of 001 for parameter A6. This operation must be
carried out by qualified personnel.
Door type:
000 = sectional door
001 = side sectional door with disengagement on obstacle
during opening too
002 = side sectional door / tilting door with soft start
If A7 has been modified, perform a reset then repeat the
learning operation (chapter 21).
Early switch-on of courtesy light for opening and closing (sec.)
0 = disabled
1 = min 2 sec
8 = max 16 sec
Function, setting range, unit
89
Factory
Value
settings
000 - 009
000 - 009
000 - 009
000 - 001
000 - 001
000 - 009
000 - 009
000 - 002
001 - 008